Vietnam Class A/B declaration vs Class C/D registration: choosing the route
In Vietnam, Class A and B medical devices go through a declaration of applicable standards (Công bố tiêu chuẩn áp dụng), while Class C and D devices require registration for circulation (Đăng ký lưu hành). Which route applies depends on the device’s risk class under Vietnamese rules. A CE certificate or Chinese registration can serve as evidence, but it does not replace Vietnamese classification or market-entry procedures.(Source: Consolidated text 08/VBHN-BYT, Articles 4, 5 and 21)
For an overseas manufacturer, the most useful output at project start is a single table: product, Vietnamese class, filing route and evidence gaps. This article covers how to build that table. For the local licence holder, the overall process and our services, see Vietnam medical device registration.
Step one: define the product scope and its Vietnamese risk class
Article 4 sets four classes, from A (low risk) to D (high risk). Under Article 5, where one intended use could fall into more than one class, or several intended uses fall into different classes, the highest class applies; devices used together are classified separately, and detailed classification rules are set by the Ministry of Health.(Source: 08/VBHN-BYT, Articles 4 and 5) You cannot drop a medical use that remains in the IFU to shorten the filing, nor simply adopt the class a competitor used for a similar product.
Classification must be carried out by the organisation that files the declaration or registration in Vietnam, and that organisation is accountable for it. If a classification understates the risk or relies on forged documents, the Ministry of Health can withdraw the result; any circulation number based on it is withdrawn, stock cleared through customs but not yet sold must be withheld and recalled, units already sold are handled according to whether they threaten patient health, and the product must be refiled under the correct class.(Source: 08/VBHN-BYT, Article 5(6), Articles 6 and 7)
Give your Vietnamese filer one consistent version of the intended use, mode of action, intended users, body contact, model differences and labelling. For IVDs, also state the analyte, whether the test is qualitative or quantitative, the clinical use and the setting. List any differences between models item by item so the filer can confirm class and filing scope; a shared product name helps with searching but settles nothing.
Where is each route filed, and what does it produce?
| Item | Class A/B: declaration of applicable standards | Class C/D: registration for circulation |
|---|---|---|
| Filed with | Provincial Department of Health where the filer’s business is located (Article 28) | Ministry of Health via the medical device online portal (Article 32); issuing new circulation numbers is delegated to the Department of Medical Infrastructure and Equipment (Circular 44/2025/TT-BYT) |
| Filer | Vietnamese enterprise, cooperative or household business (product owner or authorised), or a foreign trader’s permanent representative office in Vietnam (the trader must be the product owner or authorised by it); must have a warranty site in Vietnam or a contract with a capable warranty provider, unless an exception such as single-use devices applies (Article 25) | |
| What the authority does | On receipt of the dossier and proof of fee payment, publishes the number and dossier on the portal (technical documents excluded) | Reviews according to the applicable case and issues a registration certificate; fast-track review covers legal documents only |
| Circulation number | Declaration number | Registration certificate number |
| Validity | Generally no expiry; for emergency registrations the Minister of Health sets the term case by case (Article 21(3)) | |
| Adding models, sites, etc. | New declaration (Article 28(3)) | New circulation number (Article 29(1)(b)) |
(Source: 08/VBHN-BYT, Articles 21, 25, 28, 29 and 32; Ha Tinh provincial government portal on Circular 44/2025) After the Ministry’s reorganisation in August 2026, the Department of Medical Infrastructure and Equipment (Cục Hạ tầng và Thiết bị y tế) remains one of its units.(Source: Decree 313/2026/NĐ-CP, Article 3)
A Class A/B declaration number is a circulation number in law, just like a registration certificate. After publication the holder remains responsible for the accuracy of the dossier and the classification, and should keep the published record and the matching document versions.
Class C/D: which registration case applies?
Once a device is confirmed as Class C or D, Articles 29 and 30 determine which case applies. Evidence and review times differ considerably, so use the table below as a route-selection checklist:
| Case | When it applies | Key evidence beyond the common documents | Statutory review time |
|---|---|---|---|
| Fast track (Article 30(3)) | Certificate of free sale or marketing authorisation from a reference jurisdiction; or a previous import licence, circulation number or registration certificate for commercial sale in Vietnam | Reference approval or earlier Vietnamese approval; ASEAN CSDT; for IVDs, a Vietnamese quality assessment certificate unless a listed exemption applies, such as a reference-country marketing authorisation | 10 working days; legal documents only, with the applicant responsible for the rest and subject to post-approval checks |
| National technical regulation (Article 30(1)) | A Vietnamese national technical regulation (QCVN) applies | Certificate of conformity (hợp quy); ASEAN CSDT; certificate of free sale or marketing authorisation for imports; clinical trial approval where the law requires a trial | 30 days |
| Metrological pattern approval (Article 30(2)) | Measuring instrument requiring pattern approval under metrology law | Pattern approval decision plus the relevant documents from Article 30(1) | 30 days |
| Other devices (Article 30(5)) | None of the above | CSDT appraisal result from a unit designated by the Minister of Health, with the CSDT; Vietnamese quality certificate for IVD reagents, calibrators and controls; certificate of free sale or marketing authorisation for imports | 45 days |
| Emergency (Article 30(4)) | Devices for epidemic or disaster response on the Ministry’s emergency list that meet Article 29(3) | Reference-country authorisation or emergency-use approval, WHO emergency-use listing, among others | 10 working days |
The common documents are the application, a valid ISO 13485 certificate, the product owner’s letter of authorisation and the warranty confirmation, subject to the listed exceptions.(Source: 08/VBHN-BYT, Articles 29, 30 and 32)
The reference jurisdictions in Article 29(2) are the US FDA, Australia’s TGA, Health Canada, Japan’s MHLW or PMDA, EU member states, the UK, Switzerland, China’s central-level National Medical Products Administration (NMPA), Korea’s MFDS, and other issuing bodies recognised by the Vietnamese authorities. In practice, check the certificate type, the issuing authority and the products covered, item by item.
Chinese manufacturers should pay particular attention to the words “central level”. The text does not confirm that registration certificates or export sales certificates issued by provincial medical products administrations meet this condition, so confirm each document with your filer before submission rather than assuming it qualifies. Where a foreign certificate does not name the models to be sold, the intended use or the product owner, supply supporting evidence; a trademark or CE mark alone does not show that a whole product family qualifies for the fast track.
Article 32a separately provides for priority processing in listed cases, for example devices manufactured in Vietnam; devices whose type and product codes match a valid licence but where only the importer or registrant changes, or only the name of the manufacturing site or product owner changes (address unchanged); a new product code only because the old one was discontinued; and earlier applications whose query or refusal concerned only updating the validity of the authorisation letter, ISO 13485 certificate or marketing authorisation, or only amending the device name. The applicant must file a separate request for priority with supporting evidence, and the Ministry decides within 10 working days. A company’s launch date or a hospital’s procurement need is not, by itself, a basis for emergency registration or priority processing.(Source: 08/VBHN-BYT, Article 29(3), Article 32a(1)–(2))
Preparing documents: remove four common inconsistencies first
The Class A/B dossier is set out in Articles 26 and 27 and has nine items: the declaration form; a valid ISO 13485 certificate; the product owner’s letter of authorisation (where applicable); the warranty confirmation (single-use devices and some others excepted); a Vietnamese technical summary with the owner’s technical documentation (plus materials, manufacturing process, pre-clinical and clinical, and stability data for IVDs); a certificate of conformity or the product standard declared by the owner; the instructions for use; a sample label for Vietnam; and, for imports, a valid certificate of free sale. For imports, the decree requires the letter of authorisation, warranty confirmation and certificate of free sale to be consularly legalised. Vietnam has joined the Apostille Convention, and Decree 293/2026/NĐ-CP applies from 11 September 2026: public documents from member states with which the Convention applies in relation to Vietnam use an apostille instead of consular legalisation; documents from non-member states still need consular legalisation; and exemptions under treaties or law continue to apply. An apostille covers only public documents and not administrative documents dealing directly with commercial or customs operations, so manufacturer-issued documents such as the letter of authorisation usually need notarising first. Confirm the form required for each document with the authority before filing; for practical points, see Vietnam medical device registration now accepts apostilles. (Source: Decree 293/2026/NĐ-CP, Articles 5, 26 and 34) Quality certificates or certificates of free sale not in English or Vietnamese need a certified Vietnamese translation. Class C/D dossiers follow Articles 30 and 31 for the relevant case; emergency registrations have alternatives where consular legalisation is not available.(Source: 08/VBHN-BYT, Articles 26, 27, 30 and 31)
Whichever route applies, the following links are where problems most often arise. This table is a document-check method suggested by MediPass; it does not replace the statutory lists:
| Link | Evidence to check | Common problems |
|---|---|---|
| Product and certificates | Model list, foreign approvals, certificate of free sale, IFU | Unclear coverage of a series name; models to be sold are missing from the evidence |
| Product owner and Vietnamese filer | Product owner details, letter of authorisation, local company records | Authorising entity differs from the product owner, or scope or validity of the authorisation is insufficient |
| Manufacturing and quality system | ISO 13485 certificate and manufacturing site details | Certificate does not cover the actual manufacturing address or activity |
| Technical claims and Vietnamese versions | Technical summary, performance data, Vietnamese label and IFU | Translation widens the intended use; models or indications differ between documents |
Illustrative scenario: three models in one series
This is a hypothetical example showing the order of decisions; it does not represent any actual client or approval outcome. A manufacturer plans to sell three models of one brand in Vietnam. Two share the same intended use and operation; the third adds a new clinical use. The foreign approval lists only the first two models.
- Class: confirm the Vietnamese class of each model against its actual intended use; the new use may put the third model in a higher class.
- Scope: set out the technical and intended-use differences between models so the filer can decide what can be filed together.
- Case: if the first two models are Class C/D with a reference approval, assess the fast track; the third model cannot borrow their foreign approval. Where evidence is missing, compare two options: file first for the fully evidenced scope, or complete the evidence and file everything together.
How should processing times be read?
Class A/B: Article 28 requires the dossier to be filed with the provincial Department of Health before the device is placed on the market; the Department publishes the number on receiving the dossier, including proof of fee payment. No substantive review period is set, but that does not mean zero lead time: document preparation, consular legalisation or apostille, fee payment and checking the published status still belong in the plan, and post-market checks apply as usual.
Class C/D: Article 32 sets review times by case (see the table above). Where additions are needed, the authority must state in writing what to supplement within a set period: 25 days where a national technical regulation or pattern approval applies, 40 days for other devices, 12 working days for the fast track and 8 working days for emergency registration. If the applicant does not respond within 90 days of the notice, or the dossier still falls short after the permitted rounds (3 for the fast track, 5 for cases under Article 30(1), (2) and (5)), the application must start again. Keep calendar days and working days separate, and plan for additions and document preparation on top.(Source: 08/VBHN-BYT, Article 28, Article 32(2)–(5))
Frequently asked questions
We hold a CE or NMPA certificate. Can we simply file a Class A/B declaration?
No. Confirm the risk class under Vietnamese rules first. A foreign approval helps determine which registration case applies but does not change the device’s Vietnamese class; for Class C/D, then assess whether the fast track is available.
Can an overseas manufacturer hold the Vietnamese circulation number in its own name?
The filer must be a Vietnamese enterprise, cooperative or household business, or a foreign trader’s permanent representative office in Vietnam, where that trader is the product owner or authorised by it. Overseas manufacturers usually authorise a local company to file and arrange warranty support. For changing the holder, see Changing the registration holder in Vietnam.
Is a Class A/B declaration checked after publication?
Yes. If the class is understated or documents are forged, the classification result and circulation number can be withdrawn and products may need to be recalled; other breaches are subject to penalties. Keep the evidence and document versions used at publication, and see Vietnam medical device penalties.
The fast track reviews only legal documents. Can the technical file be lighter?
No. Fast-track review covers legal documents such as the ISO 13485 certificate, letter of authorisation, warranty confirmation and foreign approval, but the CSDT and other documents must still be submitted; the applicant is responsible for their accuracy and they are subject to post-approval checks.
Can an existing circulation number simply be updated to add a model?
Do not assume so. For Class A/B, adding a product code or manufacturing site requires a new declaration; for Class C/D, adding a product code or changing the intended use requires a new circulation number. Changes such as addresses, pack sizes, or labelling and instructions for use that do not change the intended use, indications, features or performance are handled by notification. See Post-registration changes in Vietnam.
Official references
- Ministry of Health of Vietnam, Consolidated text 08/VBHN-BYT (Decree 98/2021/NĐ-CP on medical device management, incorporating amendments by Decrees 07/2023, 96/2023, 85/2024, 04/2025 and 342/2025), Articles 4–7: classification; Articles 21 and 25: circulation numbers and filers; Articles 26–28: Class A/B declaration; Articles 29–32a: Class C/D registration cases, dossiers, time limits and priority processing, 6 March 2026, datafiles.chinhphu.vn (PDF)
- Ha Tinh Provincial People’s Committee portal, Phân cấp cấp số lưu hành và nhập khẩu thiết bị y tế (Circular 44/2025/TT-BYT delegates issuing new Class C/D circulation numbers and other tasks to the Department of Medical Infrastructure and Equipment; in force from 22 November 2025), 25 November 2025, hatinh.gov.vn
- Government of Vietnam, Decree 313/2026/NĐ-CP on the functions and organisation of the Ministry of Health, Article 3: the Department of Medical Infrastructure and Equipment as a Ministry unit, issued 8 August 2026, in force 18 August 2026, xaydungchinhsach.chinhphu.vn
- Government of Vietnam, Decree 293/2026/NĐ-CP implementing the 1961 Hague Apostille Convention, Article 5: apostille, consular legalisation and exemptions; Article 26: grounds for refusal; Article 34: in force 11 September 2026; issued 23 July 2026, datafiles.chinhphu.vn (PDF)
Prepared from official sources verifiable as of 13 September 2026 for manufacturers’ project planning; the class, registration case and dossier for a specific device must be confirmed against its actual intended use and the rules in force at the time of filing.