Before asking what Malaysian medical device registration will cost, prepare a list of the products and models you plan to sell. MDA fees depend on the risk class and the number of applications; CAB conformity assessment, technical file preparation and local licence holding are separate pieces of work. Comparing only the bottom-line total on a quotation makes it easy to count five models as five applications, or to miss third-party costs that are not yet included.

This article sets out a budgeting framework for quotations and internal approval; it does not replace product classification or grouping. For classification, routes and the overall process in Malaysia, see our Malaysia medical device registration service. CAB fees are commercial and MDA does not publish standard prices, so this article gives no market rates.

Start by listing MDA fees per application

The table shows MDA fees for a general medical device registration application, in Malaysian ringgit (RM). Class A reflects the amounts as amended by P.U.(A) 330/2025; Class B to D are the amounts in the Fifth Schedule to the Medical Device Regulations 2012 (the amendment changed only the two Class A items). The total is simply the application fee plus the registration fee and excludes CAB fees and any commercial services. (Sources: P.U.(A) 330/2025, regulations 1–2; MDA fee structure, 21 May 2026)

Risk classApplication fee RMRegistration fee RMTotal RM
Class A5007501,250
Class B2501,0001,250
Class C5002,0002,500
Class D7503,0003,750

Show the payment points separately. Under regulation 5(2)(a) of the Medical Device Regulations 2012, the application fee accompanies the application; the registration fee is a separate item under regulation 6(2), and registration runs for 5 years. Paying the fees does not mean approval: MDA decides whether to register the device after its review. (Source: P.U.(A) 500/2012, regulations 5 and 6)

A medical device that contains a medicinal product has its own fee line: MDA’s fee structure of 21 May 2026 lists an application fee of RM750 and a registration fee of RM5,000. Confirm the product’s regulatory status and risk class first, then check the applicable fee, rather than applying the table above. (Source: MDA fee structure, 21 May 2026)

Watch out for older material: some older MDA pages, and the fee table in section 6.5 of the second edition of GD/0070 (October 2025), still show a Class A application fee of RM100 and no registration fee. The GD/0070 table also gives the application fee for Class D and for a device containing a medicinal product as RM700, which differs from the RM750 in the MDA fee structure. For 2026 budgets, use P.U.(A) 330/2025 and MDA’s current fee structure, and check the amount shown in MeDC@St at payment. (Source: MDA/GD/0070 second edition, section 6.5)

How do models become applications?

Section 6.5 of GD/0070 states that Fifth Schedule fees are charged per application, for a 5-year validity period. The basis of the budget is therefore the number of applications supported by a grouping rationale, not catalogue lines or SKUs. General medical devices are grouped under MDA/GD/0005 and IVDs under MDA/GD/0054; several models can go into one application only if the relevant conditions are met. Under GD/0054, for example, a group must share one proprietary name, one manufacturer and a common intended purpose, and then meet the specific conditions for Single, System, Family, IVD Test Kit or IVD Cluster. (Sources: GD/0005 second edition announcement; GD/0054, sections 4–5)

MediPass suggests that each row of your internal budget represents one planned application and records:

  • the manufacturer, the product scope and models to be sold;
  • the risk class and grouping rationale (the clause of the relevant guidance);
  • the CAB route (not applicable for Class A, Full or Verification);
  • the MDA application and registration fees;
  • whether the grouping is confirmed. If not, also model the budget for a split.

That way sales, regulatory and finance all work from the same numbers.

Illustrative example: MDA fees under two grouping outcomes

This is a purely arithmetical assumption and does not represent a classification or grouping decision for any product. Assume four models already classified as Class C:

Grouping outcomeApplication feesRegistration feesTotal MDA fees
Two applications2 × RM5002 × RM2,000RM5,000
Split into three applications3 × RM5003 × RM2,000RM7,500

The MDA fees differ by RM2,500, but the overall project difference also depends on how the CAB confirms the assessment scope. Even where some test reports are shared, differences in use or design may call for additional evidence; equally, shared documentation may reduce duplicated preparation. Compare MDA fees, CAB work and documentation gaps together, rather than multiplying the number of applications by an “all-in unit price”.

CAB fees: clarify the assessment route and deliverables first

GD/0070 states that Class A devices are exempt from conformity assessment by a CAB and are submitted directly to MDA. Class B, C and D devices first need a CAB assessment report and certificate of conformity (valid for 5 years), which are submitted with the registration application. There are two routes: Full Conformity Assessment and Verification. (Source: GD/0070, sections 4.3, 5.1 and 5.2.3)

Under Table 1 of the second edition of GD/0070, initial Verification requires all of the following: approval from at least one recognised regulatory authority or notified body listed in Annex 1; the same design and intended purpose as the approved device; no global safety issues associated with intended use in the last year (no reported deaths, no reported serious deterioration in health, and no open field safety corrective actions, including recalls, at submission); and no rejection or withdrawal by any recognised authority. Table 2 lists special authorisations that do not qualify, such as US FDA EUA and Singapore HSA Special Access Routes. A single foreign certificate is not enough on its own to determine the route. (Source: GD/0070, section 4.3, Tables 1 and 2, Annex 1)

The second edition removed the earlier condition of “marketed for at least one year” in the reference jurisdiction and added Singapore HSA and Thailand FDA as recognised authorities, but the safety history requirement remains. Prepare quotation requests on the current conditions and the actual approval scope, rather than working back from the old threshold. Where an HSA approval is involved, see our Malaysia–Singapore regulatory reliance article. (Source: GD/0070 second edition, revision history)

CABs must be registered with MDA, which publishes the list of registered CABs on its CAB page but does not publish CAB fees. When requesting CAB quotations, MediPass suggests asking for:

  • the applicable route (Full or Verification) and the basis for it;
  • the manufacturers, products and models covered, and the relevant technical areas;
  • what the assessment report and certificate of conformity will cover;
  • the number of query rounds included, and how added scope or reassessment is charged.

These are procurement and project management suggestions, not MDA-prescribed fee items. Keep product conformity assessment costs separate from costs such as GDPMD certification for the local establishment. (Source: MDA CAB page)

Check an “all-in” quotation against four cost categories

Cost categoryMain work coveredWhat to check when quoting
MDA feesApplication and registration fees for the applicable classHow many applications are covered, whether fees are in the total, and who pays them.
CAB assessmentProduct conformity assessment and the related report and certificateRoute, product scope, and how queries and scope changes are charged.
Technical and submission servicesGap review, CSDT preparation, translation or test coordinationWhich existing documents can be used, and which tasks need another provider.
Local licence holding and operationsAR services, applicable establishment licensing, QMS and post-market workPer company or per product, annual scope, renewals and exit handover.

The budget should also state taxes, currency, cross-border payment costs and quotation validity. Laboratory testing, translation, certification or supplementary validation should not be fixed lump sums until the documents are available; list them as items to be quoted, with their trigger conditions. MediPass’s service fees are set by the relevant quotation and contract, and the price of one project is not a standard for every manufacturer.

Approve first-year registration and ongoing maintenance separately

A 5-year registration does not mean five years without costs. Local licence-holder services, applicable establishment licensing and QMS arrangements each have their own contractual or regulatory cycles, and adding models, changing products and re-registration need their own scope checks. Attach a list of ongoing maintenance items to the first-submission budget instead of hiding annual licence-holder fees in the initial registration price. For establishment licensing, see our establishment licensing service.

Re-registration is not simply a repeat of the first budget either. Check the registration details, CAB certificate and change status first, then determine the applicable procedure and work; see our article on automated re-registration in Malaysia.

Frequently asked questions

Class A and Class B have the same total MDA fees. Is the assessment work the same too?
No. The risks and compliance requirements differ: GD/0070 exempts Class A from CAB conformity assessment but not from registration, while Class B needs a CAB assessment first. That both totals happen to be RM1,250 in 2026 says nothing about CAB, documentation or service work.

If a quotation already includes MDA fees, should I add the table amounts again?
Ask the provider to list the number of applications, risk classes and official fee items included. Anything clearly included should not be counted twice; additional applications or changes in fee scope are calculated separately.

Is there a standard discounted CAB price for the Verification route?
There is no official price that applies to every project; each CAB quotes by product scope and route. MDA’s fee structure covers MDA fees only, not CAB commercial charges. Once a product is confirmed as eligible for Verification, obtain a quotation from a registered CAB for the actual product scope and make sure it is for that route.

If an application is rejected and resubmitted, are MDA fees refunded?
Under section 6.2 of GD/0070, an application is rejected if the requested information is not provided within the set period, the application fee is not refunded, and the applicant may submit a new application. That section says 90 working days, while regulation 5(3) of the Medical Device Regulations 2012 says 90 days from MDA’s request; given the difference, work to the deadline stated in MDA’s query and reply early. Check the MDA fees for resubmission, the original CAB contract and the submission service terms separately, and state in the budget what triggers additional costs.

Official references

  1. Medical Device (Amendment) Regulations 2025, P.U.(A) 330/2025, regulation 1: in force 1 January 2026; regulation 2: Fifth Schedule, Class A application fee changed from RM100 to RM500 and registration fee from “-” to RM750 (English text, PDF p. 3), published 11 September 2025, portal.mda.gov.my (PDF)
  2. Medical Device Regulations 2012, P.U.(A) 500/2012, regulation 5(2)(a): application fee to accompany the application; regulation 5(3): additional information within 90 days of MDA’s request; regulations 6(2) and 6(3): registration fee and 5-year registration; Fifth Schedule: fees, published 31 December 2012, portal.mda.gov.my (PDF)
  3. MDA, Fee Structure for Medical Device Registration (based on the Fifth Schedule and the 2025 Amendment Regulations), prepared 21 May 2026, portal.mda.gov.my
  4. MDA, General Medical Device industry page (fee table, still showing pre-amendment Class A amounts), page marked updated 7/8/2023, mda.gov.my
  5. MDA/GD/0070 second edition, Medical Device Registration Submission Guide for Conformity Assessment by Way of Verification Process and Submission of Application in MeDC@St, section 4.3, Tables 1 and 2: route conditions and excluded special authorisations; sections 5.1 and 5.2.3: Class A CAB exemption and certificate validity; sections 6.2 and 6.5: non-refundable application fee and per-application fees; Annex 1: recognised authorities, October 2025, portal.mda.gov.my (PDF)
  6. MDA/GD/0005 second edition, General Medical Device – Grouping, announcement, 30 January 2024, portal.mda.gov.my
  7. MDA/GD/0054 second edition, Guidance on the Product Grouping for In-Vitro Diagnostic (IVD) Medical Devices, section 4: basic rules; section 5: grouping categories, December 2020, mda.gov.my (PDF)
  8. MDA, Conformity Assessment Body (CAB) page (role of CABs and list of registered CABs), page updated 15 September 2026, portal.mda.gov.my

Prepared from official sources verifiable as of 17 September 2026 for manufacturers’ registration budgeting; actual fees follow MDA’s current fee structure and the amount shown in MeDC@St, and CAB fees follow the registered CAB’s written quotation.